Low-Pressure Spiral RO Membrane Element
NTR-729HF

High Water Permeability Flow at Ultra-low Pressure.
Outline
NTR-729HR demonstrates high separation performance at lower operating pressures compared to conventional cellulose acetate reverse osmosis membrane elements. The NaCl rejection is over 90%, and the performance of low molecular weight organic compound rejection is also very high.
Features
  • A low pressure RO element which uses a synthetic high polymer composite membrane (PVA), realizing over 90% NaCl rejection rate at high water permeate flow.
  • The synthetic high polymer reverse osmosis membrane deals with bacterial attacks.
  • High removal performance and water permeate flow at low pressure operations under 1MPa. Also exhibits superior removal performance of organic compounds (valuable components and TOC).
Applications
NTR-729HF is available for:
  • Ultrapure water systems for semiconductors
  • Desalination of river water and brine water
  • Concentration and refining for bulk pharmaceuticals
  • Desalination in advanced sewage treatment
Size
NTR-729HF-S8 Φ201×1,016L[mm]
NTR-729HF-S4 Φ99.5×1,016L[mm]
NTR-729HG-S4F Φ99.5×1,016L[mm]
NTR-729HG-S2F Φ61×1,016L[mm]
Performance
Element form NaCl rejection (%) Permeate flow[m3/d]
Nominal Minimum Nominal Minimum
NTR-729HF-S8 92.0 90.0 36 29
NTR-729HF-S4 92.0 90.0 8 6.5
NTR-729HG-S4F - 90.0 - 6.5
NTR-729HG-S2F - 90.0 - 2
[Measurement method] ●Evaluation solution: 0.15% NaCl solution ●Operating pressure: 0.98MPa ●Water Temperature: 25°C
●Concentrate fluid flow: S8=90L/min S4, S4F=20L/min S2F=8L/min
* The figures are a sample of observed values, not guaranteed performance.