Capillary UF Membrane Module for Ultrapure Water
NTU-3306-K4R

4-16 Mbit-enabled highly efficient final filter for ultrapure water.

Capillary UF Membrane Module for Ultrapure Water NTU-3306-K4R

Outline

Ultrapure water systems are indispensable for semiconductor manufacturing. Nitto Denko's NTU-3306-K4R is a highly efficient, reliable final filter for ultrapure water systems. This external pressure capillary UF membrane element offers excellent heat resistance, high particulate rejection properties and high water permeate flow. Nitto Denko supplies this product with full technical and after-sales service.

Features

  • High permeate flow of 7m3/h enables even large systems to be compact in design.
  • Resistivity recovers within 30 minutes.
  • Excellent heat resistance enables use of hot water up to 98°C.

Performances

Performance
Nominal molecular weight cut off Protein 6,000(20,000 with PEG)
Initial pure water flux m 3 /h, 25°C, 0.1MPa 7.0(average pressure standard)
[Remarks]
*The above values are sample observed values, not the guaranteed performance.
Specification Capillary (Hollow fiber) membrane inner/outer diameter [mm] 0.7/1.3
Effective membrane surface area m 2 14
Weight (with water full) kg 14.0
Material Capillary (Hollow fiber) membrane Polysulfone
Housing Polysulfone
Flow Screen Polysulfone
Cast resin Epoxy resin
Packing Silicone rubber
Sealing liquid 0.5% formalin solution

Operating conditions

Operating condition
Temperature °C ~40 ~70 ~85 ~98
Max. transmembrane pressure MPa 0.3 0.2 0.15 0.1
Max feed pressure 0.6 0.3 0.2 0.15
Max. permeat pressure 0.6 0.3 0.2 0.15
Max. flux m 3 /h 15(recovery>80%)
v - 1~14
[Remarks]
*They are not necessarily representing optimum operating conditions. Please contact Nitto Denko's sales representative for advice on using this product.