Low-Pressure Spiral RO Membrane Element
NTR-759HR

Excellent Nacl rejection performance and high water permeability flow at low pressure operation.

Low-Pressure Spiral RO Membrane Element NTR-759HR

Outline

NTR-759HR demonstrates a high separation performance under lower operating pressure compared to conventional cellulose acetate reverse osmosis membrane elements. The NaCl rejection rate is over 99%, and the performance of low molecular weight organic compound rejection is also very high .

Features

  • At low pressure operations of less than 1.5MPa, this model attains a comparable or higher water permeate flow than conventional mid-pressure reverse osmosis membranes operating at 3.0Mpa.
  • With the adoption of a composite membrane comprising an ultra-thin fully aromatic polyamide membrane on a polysulfone support layer, excellent NaCl rejection performance is exhibited at low pressure operation.
  • High energy efficiency and low operating costs are achieved with its high performance at low pressure operation.

Applications

NTR-759HR is available for:

  • Primary pure water systems, sub-systems, and recovery systems of ultrapure water systems it is used in the semiconductor industry.
  • Concentration processes, NaCl rejection, or recovery of valuable components from waste water it is used in the food industry.
  • Recovery of valuable resources it is used in various industries.

Sizes

NTR-759HR S8 Φ201×1,016L[mm]
S4 Φ99.5×1,016L[mm]
S4F Φ99.5×1,016L[mm]

Performance

Element form Rejection[%] Permeate flow [m3/d]
Nominal Minimum Nominal Minimum
NTR-759HR S8 99.5 99.0 30 26
S4 99.5 99.0 7 6
S4F - - 6
[Measurement method]
Evaluation fluid: 0.15 NaCl solution
Operating pressure: 1.47MPa
Water temperature : 25°C
Concentrate flow rate: S8=90L/min S4, S4F=20L/min
[Remarks]
*The figures are a sample of observed values, not guaranteed performance.

Rejection ratio of various solutes [%]

MgSO4 99.9
SiO2 99.3
Isopropyl alcohol 97
Glucose 99.8
Sucrose >99.9
[Measurement method]
Operating pressure: 1.5MPa
[Remarks]
*The figures are a sample of observed values, not guaranteed performance.

Product Informatio